SYSTEM OPERATION
• When the green light is ON the slide is clear and it is ok for a rider
to be dispatched.
• When rider enters the slide the Acculogic™ sensors located at the entrance of the slide tell the system that a rider has entered the slide, and change the light to RED.
• While the light is RED, the slide is occupied, and it is unsafe to dispatch a rider into the slide.
• When
the rider exits the end of the slide the lower Acculogic™ sensors tell
the system that the rider has exited the slide and after a user configurable
time delay the system will turn the light from RED to GREEN to indicate
that it is ok to dispatch a new rider.
POWER REQUIREMENTS:
120V – 5 AMPS at Start Tower and Finish Line Gantry
EQUIPMENT LIST:
1 LL-102 LED Signal Head (10x10x8) per lane
1 LL-300 Upper Control Box (9x9x7)
1 LL-308 Lower Control Box (20x18x10)
1 LL-200 AccuLogic Signal Emitters per 2 lanes
1 LL-205 AccuLogic Signal Receivers per lane
1 LL-700 Waterproof access port per 2 lanes
2 LL-502 Polycarbonate lenses per lane
1 Lot Quick Disconnect Cables
1 Lot Installation Hardware and Brackets
1 Finish Line Gantry truss System